RESET
The COM card also has a reset button which resets all the Cards installed as well as an input for the ASI.
See individual Control Card Manuals for details on each card type.
Installation of Cables
Plug the AC power cord into the rear of the controller. Attach the cable between the filterwheel and the
controller. Connect the serial cable between the computer and controller.
WARNING: Ensure that the
power switch is in the “OFF” position while connecting or disconnecting connectors including the mains
power plug. Connecting and disconnecting with the power on can result in permanent damage to the
controller electronics.
The controller relies on proper orientation of the terminals on
the mains input plug. The ground terminal must be properly
earth grounded to provide safe protective grounding. Where
possible, correct connection of Neutral and Hot convention
should be followed.
Warning: Failure to follow Hot / Neutral conventions can result in failure of fuse shorting protection.
Danger: Failure to ground the ground terminal can result in failure of protection against electrical shock.
When setting up the controller several things should be taken into consideration. One, the controller
should not be setup in a location where access to the power cord is blocked. Although heat build up is
generally not an issue, the controller should be placed where it can get adequate ventilation to the
bottom air vents. The on/off power switch on the front of the controller should be easily accessible.
The controller should be close enough to the filter wheel / shutters that there is no strain on the
attachment cables.
Fuse
Ground
Neutral
Hot