Problem
Cause
Corrective Measure
The machine does not operate even though the power switch is
turned ON.
•
Power is not supplied.
•
Check the connection of the power supply of the AC power
adapter.
•
A screw hasn’t been removed from the pick up location for a
certain amount of time.
•
Take the screw out from the pick up location.
•
Adjust the timer setting knob.
•
Too many screws were loaded into the hopper.
•
Reduce the quantity of screws in the scooping to a proper load
level.
•
Presence of a foreign object
•
Remove the foreign object.
•
The AC adapter is faulty.
•
Contact ASG.
Screws do not move properly.
•
Screws with a larger diameter than the specified rail size were
loaded or screws with a different diameter were mixed in together.
•
Use screws with the specified nominal diameter.
•
Remove the screws with the different nominal diameter.
•
An insufficient quantity of screws are in the hopper.
•
Add a proper quantity of screws into the hopper.
•
Screws in an abnormal position in the passing plate cannot be
swept away with the brush.
•
Adjust the brush.
•
Adjust the passing plate. If a proper amount of screws are loaded
into the hopper, the status may be improved.
•
The axis of the screw thread entered the passing plate.
•
Remove the screw and check and adjust the passing plate.
•
A screw has stopped in an incorrect position while moving on the
rail.
•
Remove the screw. Take care not to damage the rail.
•
Move the holding plate upward to remove the screw. After, adjust
the position of the holding plate.
•
The rail does not vibrate.
•
Check to see if a screw is obstructing the vibration. If it is, remove
the screw.
•
Check the vibration adjustment.
•
Check that the scraper does not make contact with the hopper
wall. If no screw is obstructing the clearance, consult ASG.
A screw has fallen into the rail groove.
•
Screws with a smaller diameter than the specified rail size were
loaded.
•
Use screws with the specified nominal diameter and length.
The screws in the rail are not flowing properly.
•
The clearance between the holding plate and the head of the
loaded screw is too small.
•
Adjust the holding plate. Adjust the vibration. If, after following
the instructions written above, the machine still does not function
properly, consult ASG
•
The rail is oily or dirty.
•
Clean the rail.
•
The rail does not vibrate.
•
Remove the screws caught in the clearance. If there is no screw
that is caught, consult ASG.
•
Check that the vibration level is properly adjusted.
•
The motor is worn or malfunctioning.
•
Replace the motor.