Application with Robotic System
External Output Signals
The jack on the back of the machine detects the presence of screws on the rotational
escape, which shall be used with automatic assembly machines or external screw
counters.
FUNCTION:
Screw present: signal high (ON)
• Incoming current: shall be limited to less than 100mA
• CAUTION:
Additional resistor is required on external circuit for regulating
current.
CAPACITY:
Max DC current: 100mA
• External supply voltage: 5 - 24VDC (Max: 27VDC)
• CAUTION:
Please use the plug type of 3.5 - 3 conductor miniature jack.