ASCO CARBON DIOXIDE LTD
Offi cial sales partner USA
Industriestr. 2, CH-8590 Romanshorn
GRAND NORTHERN PRODUCTS
Tel. +41 71 466 80 80 Fax + 41 71 466 80 66
Tel. + 001 616 583 50 00 Fax + 001 616 583 90 61
/www.ascoco2.com
[email protected]/www.grandnorthern.com
ASCO
CARBON DIOXIDE LTD
33
5
MAINTENANCE
1
Screw
2
Lower part
3
Nut
4
Disc
5
Filter inlay
6
Upper section
• Loosen 4 screws.
• Remove the lower part.
• Unscrew the nut.
• Remove the disc.
• Remove the fi lter inlay and replace it with a new fi lter inlay.
• Reassemble the water separator in the reverse sequence.
5.5
TESTS
According to the specifi cations of BGV D 26, the following tests must be conducted by
a technical expert. The results of the tests must be documented in a test report. The
device operator must carefully store the test report until the next test.
5.5.1 After a working break of more than one year
• Check the device to make sure that it is in a proper condition and is functioning well.
5.5.2 After changing the installation site
• Check the device to make sure that it is in a proper condition, is functioning well and
has been installed properly.
The operational safety of the device can get hampered on account of maintenance jobs
or any modifi cations that have been done.
• Check the device to make sure that it is in a proper condition, is functioning well and
has been installed properly.