ASCO CARBON DIOXIDE LTD
Offi cial sales partner USA
Industriestr. 2, CH-8590 Romanshorn
GRAND NORTHERN PRODUCTS
Tel. +41 71 466 80 80 Fax + 41 71 466 80 66
Tel. + 001 616 583 50 00 Fax + 001 616 583 90 61
/www.ascoco2.com
[email protected]/www.grandnorthern.com
ASCO
CARBON DIOXIDE LTD
21
3
INSTALLATION
3.3.2 Establish main contact
DANGER
Risk of electric shock.
The socket to be used must be installed by an electrician and be in compliance
with IEC 60364-1.
The machine must have an FI fuse of type B, 30 mA.
Check the main cables of the machine every time before use to ensure that it is not
damaged. Never operate a machine with damaged cables. Get the damaged cables
replaced by an electrician. The extension cord must be protected by IP64 safety me-
chanism and the cables must at least be in compliance with HAR H05VV5-F-1.5.
• Insert the main plug into the socket.
WARNING
To reduce the risk of electrocution, keep all connections dry and off ground. Do
not touch plug with wet hands.
3.3.3 Grounding instructions
This product must be grounded. In the event of any electrical short circuit, grounding re-
duces the risk of electric shock by providing an escape wire for the electric current. This
product is equipped with a cord having a grounding wire with an appropriate grounding
plug. The plug must be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances.