FELSÖKNING OCH ÅTGÄRDER
FAULT
CAUSE
WHAT TO DO
The burner stops
The burner and/or boiler
need(s) sweeping
Clean the burner and boiler
The burner stops,
Fault code ErrSafe
The burner has overheated
Clean the burner and boiler.
Reset the fall pipe’s overheat
protection
The burner stops,
Fault code ErrStart
The burner has not lit
Check the pellet supply and the
starter dose “Ign dose”
The burner stops,
Fault code ErrLow
The burner has gone out in
low output mode
Check the pellet supply and the
“Feed LO” and “Air LO” settings
The burner stops,
Fault code ErrHigh
The burner has gone out in
high output mode
Check the pellet supply and the
“Feed HI” and “Air Hi” settings
The burner stops,
Fault code GOutStrt
The burner lit but then went
out during pre-operation
Check the pellet supply and the
“Feed SU” and “Air Su” settings.
(ServCode)
The burner stops,
Fault code ErrorIgn
The firing element is not
drawing any power
Check the connections to the
firing element or replace the firing
element
The burner stops,
Fault code Tempsens
The control circuit board has no
contact with the temp. sensor
The temperature sensor circuit
may be broken by the external
thermostat or switch. If not, check
the connections to the temp.
sensor or replace
The burner stops from
time to time and without any
visible cause
May be due to too large or
strong variations in vacuum in
the chimney, or fuel feed fault
Contact your authorised installer for
overhauling and any installation of
draft inhibitors