Menu PX52
1
.
r
e
n
r
u
b
e
h
t
p
o
t
s
r
o
t
r
a
t
s
o
t
m
r
i
f
n
o
C
?
t
r
a
t
S
5
View
Start T
70 (0-90)
Boiler start temperature in ° C.
Firedet
000-999
Actual flame sensor reading.
lower than Stop T
Current
000-999
Actual current consumtion reading.
Stop T
80 (0-90)
Boiler start temperature in ° C.
Syspoint
000-999
Actual syspoint i program
higher than Start T
Temp 1
00-99
Actual temperature reading 1 in ° C.
2 UserMenu
Jump to User Menu
Temp 2
00-99
Actual temperature reading 2 in ° C.
Back
Pgm V
5.1
Actual program version.
# Ignit
000-999
Number of ignitions since latest reset.
2
UserMenu
Therm K
Not Active
3 Settings
Jump to Settings Menu
OpTiHour(Min)
000-999
External auger running time since
4 Service
Jump to Service Menu
latest reset in hours or minutes.
5 View
Jump to View Menu
TachoAct
000-999
Tachometer readings from fan.
6 ClockSet
Back
Back
6
ClockSet
3
Settings
00:00
Set Time (HH:MM)
SetCode(21)
01-01-01
Set Date (YY-MM-DD)
4 Service
Back
Ign dose
70 (010-240) Ignition dose in seconds.
TstDose
Testing of ignition dose.
Feed HI
10,9 (0-20)
Feeder HI-Power mode in seconds.
Feed LO
7,2 (0-20)
Feeder LO-Power mode in seconds.
Feed MIN
4,0 (0-20)
Feeder MIN-Power mode in seconds.
Air HI
50 (0-100)
Fan HI-Power mode in percent.
Air2 HI
55 (0-100)
Fan2 HI-Power mode in percent.
Air LO
35 (0-100)
Fan LO-Power mode in percent.
Air2 LO
45 (0-100)
Fan2 LO-Power mode in percent.
Air MIN
20 (0-100)
Fan MIN-Power mode in percent.
Air2 MIN
35 (0-100)
Fan2 MIN-Power mode in percent.
HI I/0
1 (0-1)
Activate HI-Power mode.
LO I/0
1 (0-1)
Activate LO-Power mode.
MIN I/0
0 (0-1)
Activate Min-Power mode.
Default?
Set default values.
Language
2 (1-5)
Set language
1 = Swedish
2 = English
3 = Finnish
4 = German
5 = French
6 = Italian
Back