background image

Zip Econoboil - Installation & Operating Instructions - 81441 - July 2015 v1.03 

Page 1 of 16

Installation and Operating Instructions

Zip Econoboil

Budget priced instant boiling water for canteens and kitchens.

03042  Zip Econoboil 3.0 litre White 
05042  Zip Econoboil 5.0 litre White  
07042  Zip Econoboil 7.5 litre White  

103042     Zip Econoboil 3L White 
105042     Zip Econoboil 5L White 
107042     Zip Econoboil 7.5L White

EB003
EB005
EB007

Summary of Contents for Econoboil EB003

Page 1: ...ing Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens 03042 Zip Econoboil 3 0 litre White 05042 Zip Econoboil 5 0 litre White 07042 Zip Econoboil 7 5 litre White 103042 Zip Econoboil 3L White 105042 Zip Econoboil 5L White 107042 Zip Econoboil 7 5L White EB003 EB005 EB007 ...

Page 2: ... a Plumbing 5 b Venting 5 c Electrical 5 d Connect Timer 6 Step 4 Assembling 6 Step 5 Commissioning 6 Operating Procedures 7 Earthing Continuity Verification 10 Problem Solving 10 Wall Mounting Template Dimensions 11 Cleaning 11 End of life disposal 11 Spare Parts 12 Exploded View Diagram 13 Contact Details 16 Note All plumbing must comply with the relevant parts of AS NZS 3500 All electrical must...

Page 3: ...r supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fittings The ambient temperatures this unit must operate withi...

Page 4: ...ion the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Fastening Position mounting hole template on wall and dri...

Page 5: ...e location as under certain conditions it may discharge cold or boiling water and or steam For exposed vent plumbing connect vent outlet from the base of heater to a 1 2 or 12 7 mm pipe which has a continuous fall is no more than 3 metres long has no more than 3 right angle bends and discharges to a waste water drain For concealed vent plumbing connect plumbing to the vent outlet from the heater r...

Page 6: ...e escutcheon without pressure see Fig 5 Continue to turn the tap one full rotation maximum until the handle is fully vertical Step 5 Commissioning Check previous steps Turn water supply ON Water is now flowing into heater check connections for leaks Wait approximately 5 minutes and check outlet tap for water This is acheived by pulling the tap handle forward Power is only to be turned on when wate...

Page 7: ...g 5 2d If this is not shown the Lithium battery will need to be replaced or the battery isolation strip has not been removed To access the control panel remove the clear plastic dust cover from the front of the timer NB Always reattach the clear plastic dust cover on the timer after making any changes 1 Set program mode This function is for user to customise unit ON OFF time Press DAY button to se...

Page 8: ... To set the time for the unit to turn on press the DAY button to scroll through Mo Fr Sa and Su 5 2d mode or Mo Tu We Th Fr Sa Su 24H mode or Mo Su 7D mode Press HOUR and MIN buttons respectively until required time is reached To set the time for the unit to turn off press TIMER button and 1OFF will be displayed Press HOUR and MIN buttons respectively to set the turn off time To set the next ON OF...

Page 9: ...n the timer is in ON mode Once the OVERRIDE button is pressed the timer will change to the OFF sta tus This will switch the unit off during the override period While the override hour is in operation a countdown clock will appear on the LCD screen See Fig 7 At the end of the override period the timer will revert back to the ON mode Temporarily ON Override when the timer is in AUTO mode Timer will ...

Page 10: ...s not exceed 1 ohm If required an earth continuity test can be performed by testing between the earth pin on the products lead and a exposed piece of metal on the case Symptom Possible Cause Solution Fails to dispense water Water isolating valve turned off Blocked filter blocked meter tube blocked strainer jammed ball valve assembly airlock in transfer tube Check water supply valve Contact Zip aut...

Page 11: ...e spray or abrasive cleaners Clean the case with a soft cloth or brush and mild soap and water Wall Mounting Template Dimensions 3 0 L 3 0 L 3 0 L 414 3 0L End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details ...

Page 12: ... 90102 CISTERN FLOAT KIT W NUT SCREW 9 90495 BANJO SCREW HYDROBOIL 2000B 10 90501 TAP TOP KIT HYDROBOIL 11 90512 ESCUTCHEON KIT EB2000B 12 90502 TAP ASSY COMPLETE 13 90081 THERMOSTAT KIT 14 90045 ELEMENT KIT 1500W 3Litre 14 90085 ELEMENT KIT 2400W 5 7 5Litre 15 90107 FILTER KIT COLD INLET BUSH 16 90175 DRAIN PLUG KIT MB HB AB EB STAINLESS STEEL CISTERN VERSION 17 90487 CISTERN LID CLAMP KIT HB AB ...

Page 13: ...Zip Econoboil Installation Operating Instructions 81441 July 2015 v1 03 Page 13 of 16 Exploded View Diagram ...

Page 14: ...Page 14 of 16 Zip Econoboil Installation Operating Instructions 81441 July 2015 v1 03 Notes ...

Page 15: ...Zip Econoboil Installation Operating Instructions 81441 July 2015 v1 03 Page 15 of 16 Notes ...

Page 16: ...t Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia Website www zipwater com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods ...

Reviews: