ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ και ΕΓΚΑΤΑΣΤΑΣΗΣ

Emix

Emix TANK 220

Emix TANK 300

EG

I

F

D

E

P

GR

Summary of Contents for EMIX

Page 1: ...STRUCTIONS ISTRUZIONI D USO E D INSTALLAZIONE NOTICE D UTILISATION ET D INSTALLATION BEDIENUNGS UND INSTALLATIONSANLEITUNG INSTRUCCIONES DE USO Y INSTALACION MANUAL DE INSTRUÇÕES E INSTALAÇÃO ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ και ΕΓΚΑΤΑΣΤΑΣΗΣ Emix Emix TANK 220 Emix TANK 300 EG I F D E P GR ...

Page 2: ...ction centres or to a dealer providing this service Disposing of an electrical and electronic equipment and its batteries separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be recovered and recycled to obtain significant savings in energy and resources In order to underline the duty to dispose of thi...

Page 3: ...ables for each type of line When connecting refrigerant tubing Keep all tubing runs as short as possible accordingly to the allowable distances from the outdoor unit see manual Use the flare method for connecting tubing Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them screw by hand and then tighten the nut with a torque wrench for a leak free...

Page 4: ...perly grounded with a ground or earth wire or through the supply wiring l Wiring must be done by a qualified electrician l If the unit hasn t been used for a long period to warm up the system the power mains must be turned on at least 1 hour before operation Safety instructions l Read this booklet carefully before using this appliance If you still have any difficulties or problems consult your dea...

Page 5: ...ged by the electronics of Emix tank or manually by the end users the mixing valve to manage properly the hot water temperature electric connections to manage the tank by iSeries and to power it by single phase or three phase power supply Emix tank is both a proper heat pump tank and a full feature electrical water heater Emix tank must be connected to an outdoor unit of the iSeries range equipped ...

Page 6: ...ion units a hydrokit for a floor system and an Emix tank coexist all connected to a G110 Rating data Emix tank 220 Emix tank 300 Power supply 230 V 1 50 Hz 380 V 3 50 Hz Minimum power input 4 W 0 05 A Max power input 70 W 0 53 A Water connection 3 4 G 3 4 G Refrigerant connection R410A 3 8 3 8 Net weight 95 Kg 114 Kg Dimensions H W D 1460x598x618 mm 1875x598x618 mm Electric backup heaters 3 kW It ...

Page 7: ...k as electrical water heater without the iSeries heat pump As first step you have to remove the bottom cover simply by your hand it is not fixed by screw and you have only to pickup it by the basement 1 Control panel 2 Main switch selector switch 3 Thermostat locked to 85 C 4 Cold water inlet 5 Hot water outlet 6 Solar coil inlet 7 Solar coil outlet Detaching bottom sheet Bottom front sheet is det...

Page 8: ... 4 HOT WATER OUTLET 5 PRESSURE RELIEF VALVE OUTLET 10 bar 6 REFRIGERANT IN 7 REFRIGERANT OUT 8 ELECTRIC INLETS 9 BOILER THERMOWELL FOR SOLAR SYSTEM HEIGHT 220 LITRE UNIT 1460 mm 300 LITRE UNIT 1875 mm WEIGHT 220 LITRE UNIT 95 KG 300 LITRE UNIT 114 KG Additional information ...

Page 9: ...8 OUT is the pipe to the outdoor unit Pay the max attention to respect the sense of that connections both if you are using Emix tank connected to the EMX port or the standard port of the outdoor unit Here below the water connection and mixing valve please provide an expansion tank 18 lt or more water filter before the cold water connection in order to save the quality of components and connect the...

Page 10: ...rigerant Circuit Emix tank is a component that may be connected to the other types of indoor units of the iSeries range at the same time and without specific limitations by using the special connection for Emix tank and duly considering the length of the Emix tank pipe to be added to the total length set by the outdoor unit we advise a specific insulation of the Emix tank pipes to guarantee the mi...

Page 11: ...i application Total indoor unit tubing length 50 meters Emix tank tubing length 7 meters Total tubing length including Emix tank 57 meters G80 limits in quadri application is 65 meters with additional load You have to add 15 g m x 17 m Choose the configuration by the number of indoor units excluding Emix tank unit and by the outdoor unit model Check connection limits including Emix tank unit dista...

Page 12: ...n accordance with existing regulations The installation must be protected by a double pole circuit breaker not included Remove the front panel by the same approach of the base part There are no screew to be removed and no wire to be disconnected After you removed the front panel you will see the tank and in the bottom right part you will see the cover of electrical connections COUPLING SPACE COVER...

Page 13: ...LED flashing Alarm and remote control are two connection giving you the opportunity to control the Emix tank by remote wired connection as sample from a Solar Panel Control Box or by Timer The electric schema is applied on the unit by a proper label Note 1 Emix tank electrical consumption is very low but in case electrical heater elements are activated Emix tank has to support the flow of big amou...

Page 14: ...continuously If within 72 hours 3 days none of the above conditions have bee satisfied automatically the water set point is moved up to 60ºC if lower to perform the cycle The yellow LED is switched on If there are electrical elements connected they can be used during anti legionella cycle During the cycle if none of the above conditions is verified and by water temperature trend analysis the softw...

Page 15: ...ic back up management Automatic modes Emix tank software can automatically manage electric back up heaters under certain conditions This mean that these operation modes are not to be set and that can not be deactivated They are Antifreeze mode Cold draft prevention Electric water heater mode Electric back up management Antifreeze mode If water temperature inside the buffer tank is lower than 10 C ...

Page 16: ... C without external energy sources electric heaters or similar However no errors will be displayed if water temperature set will be over 60 C Only DHW application Connect Emix tank units to standard refrigerant ports on outdoor unit 1 4 3 8 and 1 2 3 8 adapters are to be field supplied Do not disconnect Emix port bypass Remove JP1 from every Emix PCBs The system will operate always in heating mode...

Page 17: ...the push black button and not when you press it Then when Emix is active it will indicate the water temperature inside the tank If you want to setup the water temperature you have to speedy press and release the push button enough time to see ON the green LED equivalent to the water temperature you want to set then please wait five seconds and the Emix will go back in the working mode status indic...

Page 18: ...overy unit to one of the liquid valve of indoor units recover the refrigerant inside the outdoor unit disconnect the recovery unit and be sure that the EMX port valves are open How to connect Emix tank tank tank to a solar thermal system Emix tank tank could be connected to any type of thermal solar system both natural and forced circulation In case of forced circulation solar system by the water ...

Page 19: ...19 EG ...

Page 20: ...20 EG ...

Page 21: ...21 EG ...

Page 22: ...22 EG ...

Page 23: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com ...

Page 24: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima com ...