EN – 33
Install Chute Rotation Gear
1.
Position actuation gear so gear teeth are at lowest
position.
2.
Install chute rotation gear so midpoint of lower gear
teeth are seated in chute lock arm.
3.
Make sure calibration markers on actuation gear and
chute rotation gear are aligned.
4.
Position chute rotation lever upright.
5.
Position discharge chute facing forward.
6.
Reinstall hex rod into chute gear and secure with
hairpin.
7.
Reinstall chute gear cover and secure with tapping
screw.
8.
Adjust discharge chute. Refer to Operator’s Manual
for adjustment procedure.
9.
Reconnect spark plug wire.
IMPORTANT:
Check all adjustments after first use.
Remove Actuation Gear
NOTICE:
Save all hardware for reinstallation.
1.
Stop engine, remove key and wait for all moving parts
to stop and for hot parts to cool.
2.
Disconnect spark plug wire from engine.
3.
Remove chute rotation gear. See
Remove Chute
Rotation Gear
on page 32.
See Figure 60.
4.
Remove actuation gear and two flat steel washers
from chute gear bracket.
Install Actuation Gear
1.
Install two flat steel washers onto actuation gear.
2.
Install actuation gear into chute gear bracket and
position so gear teeth are at lowest position.
3.
Reinstall chute rotation gear. See
Install Chute
Rotation Gear
on page 33.
Figure 58
1. Center Locking Flange Nut
2. Flange Bushing
3. Hex Bolt
4. Chute Rotation Gear
1
4
3
2
Figure 59
1. Actuation Gear
2. Chute Rotation Gear
3. Chute Lock Arm
4. Calibration Markers
1
2
3
4
Figure 60
1. Actuation Gear
2. Flat Steel Washer
3. Chute Gear Bracket
1
2
3