EN – 10
SEPARATE AUGER HOUSING FROM
FRAME
NOTICE:
Save all hardware for reinstallation.
1.
Stop engine, remove key and wait for all moving parts
to stop and for hot parts to cool.
2.
Disconnect spark plug wire from engine.
See Figure 7.
3.
Remove hardware retaining chute gear cover to chute
pedestal and remove cover.
4.
Remove hairpin from hex rod and remove hex rod
from chute gears.
5.
Remove cable hanger from hex rod.
6.
Remove hex rod from dash panel.
See Figure 8.
7.
Remove hairpin and cable eyelet from chute control
assembly.
8.
With a pliers, squeeze tabs on cable snap and remove
cable snap from chute control assembly.
9.
Guide cable end through lower hole in chute control
assembly and through hole in dash panel.
10. Reinstall hairpin to chute control assembly so sleeve
bushing and hairpin are not misplaced.
See Figure 9.
11. Remove hairpin, sleeve bushing and cable eyelet from
deflector arm under dash panel.
12. Remove cable snap from deflector anchor.
Figure 7
1. Tapping Screw
2. Chute Gear Cover
3. Hairpin
4. Hex Rod
1
2
4
3
Figure 8
1. Hairpin
2. Chute Control Assembly
3. Sleeve Bushing
4. Cable Snap
5. Chute Lock Cable
6. Cable Eyelet
1
2
5
4
3
6
Figure 9
1. Sleeve Bushing
2. Hairpin
3. Cable Snap
4. Deflector Arm
5. Deflector Anchor
1
2
5
3
4