3.2 Functional block HVAC
This parameter block is only active if an Expert/Master configuration is
selected and HVAC mode is active.
Functional block HVAC - Parameters
Default operation mode
Comfort
Standby
Eco/Night
Building protection
Determines which operating mode is chosen if automatic HVAC mode not used.
Default: Standby
Force objects 1 - 3
Priority
Equal
When setting „Equal“ is choosen the new operating mode becomes active
immediately, the other two force objects are deactivated.
Hierarchical 1-3
In the hierarchical setting, operating mode 1 has the lowest and operating mode 3
the highest priority.
See also 3.14 priorities
Operation mode 1
Comfort
Standby
Eco/Night