5. Commissioning
5.1 KNX-LUNOS-CONTROL4-IW
The KNX clamp is connected to the KNX bus via the supplied terminal block (red (+) / black (GND)). The
auxiliary voltage is connected via the supplied terminal block (yellow (+) / white (GND)). The fans are
mounted according to the lunos specification and connected via the supplied preceded connector.
Optionally, potential-free button / switch can be connected via the supplied connector.
Under no circumstances may the module be connected to mains voltage potential.No mains
voltage potential may be carried in the flush -mounted socket used. Installation may only be
carried out by a specialist.
The pre-assembled connector must be connected to the cables of the fans as follows
Fan connection
ACM-Module connection
violet
violet
0-10V
red
red
+12V
blue
blue