Domestic Ventilation with Heat Recovery
KNX-LUNOS-CONTROL4
Subject to change
Arcus-EDS GmbH
www.arcus-eds.de
Rigaer Str. 88 10247 Berlin
[email protected]
Tel.: +49(0)30 25933914
Fax.: +49(0)30 25933915
682x-Lunos-Control-4F
V.13.09.2022
e1
3.8 Functional block exhaust
This function block is only available if a configuration with a exhaust air
option is selected.
Functional block exhaust - Parameters
Lag time
0 .. 60 Minutes
After the lag time, the fan pair 2 goes back to basic air exhaust mode.
Lead time
0 Seconds bis 5 Minutes
If the input is active, the fan pair 2 goes into the exhaust air operation after the lead time,
Object 22 is activated.
Active time --- interval period
Continuous operation
1 min -- 5 min
2 min -- 5 min
1 min -- 15 min
2 min -- 15 min
5 min -- 15 min
1 min -- 30 min
2 min -- 30 min
5 min -- 30 min
10 min -- 30 min
During the interval period, the exhaust fan is active for the duration of the active time.
Selection fan type
Silvento FK