Domestic Ventilation with Heat Recovery
KNX-LUNOS-CONTROL4
Subject to change
Arcus-EDS GmbH
www.arcus-eds.de
Rigaer Str. 88 10247 Berlin
[email protected]
Tel.: +49(0)30 25933914
Fax.: +49(0)30 25933915
682x-Lunos-Control-4F
V.13.09.2022
e1
5.2 KNX-LUNOS-CONTROL4-REG
The KNX clamp is connected to the KNX bus via the supplied terminal block (red (+) / black (GND)). The
auxiliary voltage is connected via a screw clamp. The fans are mounted according to the lunos
specification and connected via the screw terminals.Optionally, potential-free button / switch can also
be connected via screw terminals.
Under no circumstances may the module be connected to mains voltage potential. The
installation may only be carried out by a specialist.
5.3 Connection options for different lunos fan types
Fan-type
L1.A
L1.B
L2.A
L2.B
NEXXT
X
X
E²
X
X
X
X
pairwise
EGO S1[R]
X
X
EGO S2[L]
X
X
Silvento (FK, EC,
30/60/100)
X
X