37
Testing RPS Switch
1. Disconnect the RPS switch connector coming out
from the rear throttle control housing; then connect
the ohmmeter leads to the yellow wire and black
wire.
2. With the throttle lever in the idle position, the meter
must read less than 1 ohm. If the meter reads OL
(infinite resistance), replace the control assembly.
3. Move the throttle lever to the wide-open position.
The meter must read OL (infinite resistance). If the
meter reads less than 1000 ohms, replace the rear
throttle control assembly.
Testing Idle Switch
1. Disconnect the idle switch connector coming out
from the front throttle control housing; then connect
the ohmmeter leads to the red wire and black wire.
2. With the throttle lever in the idle position, the meter
must read OL (infinite resistance). If the meter reads
less than 1000 ohms, verify the switch is being com-
pressed by the throttle lever by putting pressure on
the end of the throttle lever in the direction of the
arrow.
ZR-170
3. If the meter now reads OL (infinite resistance) with
pressure on the throttle, the throttle cable will need to
be adjusted. Refer to the throttle cable section in the
service manual. If the meter still reads less than 1000
ohms, replace the front throttle control assembly.
4. Move the throttle lever to the wide-open position.
The meter must read less than 1 ohm. If the meter
reads OL (infinite resistance), replace the front throt-
tle control assembly.
Testing Handlebar Warmer
Elements
NOTE: Resistance will vary due to temperature;
therefore, this test should be made at room tempera-
ture of 22° C (72° F).
1. Open the hood; then disconnect the handlebar
warmer two-wire connector.
2. Connect one ohmmeter lead to the yellow lead; then
connect the other ohmmeter lead to the green lead.
ONS-019
3. The meter must read 14.4 ± 10% ohms.
4. Replace any element measuring less than or more
than the specified amount.
5. Repeat test for the other element; then connect the
leads. Close and latch the hood.
Testing Handlebar Warmer
Switch
1. Open the hood; then disconnect the main harness
wires from the switch.
2. With the handwarmer toggle in the OFF position,
connect one ohmmeter lead to pin and the other ohm-
meter lead to pin. The meter must read OL (infinite
resistance).
ONS-018