Page - 73
Displays "
SET TO SWITCH REMOTELY
"
ISSUE
If when pressing the "Pool / Spa" button the display flashes the message "
SET TO SWITCH
REMOTELY
", the heat pump is using a remote relay switch or a 3-wire controller.
RESOLUTION
l
The Pool and Spa thermostat automatically switch when using these modes.
l
Operation manually will not be available when using these external devices. No action is required.
Displays "
SET UNIT MODEL NUMBER
"
ISSUE
The heat pump has encountered a software error.
RESOLUTION
l
The model number and serial number will need to be re-entered into the system. The system will then
operate as normal.
l
If the issue reoccurs, please contact AquaCal
®
Technical Support.
Heat Pump Not Running
ISSUE
The heat pump will not run.
RESOLUTION
1. Confirm equipment is receiving power. Is the heat pump display illuminated?
l
If not, confirm the main breaker (located at the power supply panel) and the disconnect switch (located
near the heat pump) are both turned on.
l
If the display still does not illuminate, it is recommended that the heat pump installer or electrician
confirm the heat pump is receiving power.
2. Confirm correct mode is selected.
3. Confirm thermostat is set correctly.
l
When heating the water is desired, the thermostat should be set above the current water temperature.
l
When cooling the water is desired, the thermostat should be set below the current water temperature.
4. If an error code is displayed, diagnose and correct the cause of the code.
l
5. If the heat pump is using an external controller, the heat pump may not be set correctly to accept the
controller’s signal.
Heat Pump's Tripping Breaker
ISSUE
The heat pump breaker(s) keeps tripping.
RESOLUTION
1. If AquaCal
®
heat pumps have been connected using a multiple heat pump configuration, the configuration
may be incorrect. Please confirm settings or contact installer of equipment.
l
Connecting Multiple Heat Pumps (Master / Slaved)
2. Have an electrician confirm breakers are correct type, in good condition, and properly sized for the heat
pump.
2
-
T
roubl
es
hoot
ing
Summary of Contents for HeatWave SuperQuiet SQ120R
Page 2: ......
Page 28: ...Page 24 Configure Call Flex Enter Installer Menus then proceed 1 Installation ...
Page 33: ...Page 29 Configure for Smart Bus Controller Enter Installer Menus then proceed 1 Installation ...
Page 36: ...Page 32 Configure 2 wire controller Enter Installer Menus then proceed 1 Installation ...
Page 40: ...Page 36 1 Installation ...
Page 41: ...Page 37 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation ...
Page 42: ...Page 38 1 Installation ...
Page 45: ...Page 41 1 Installation ...
Page 47: ...Page 43 1 Installation ...
Page 50: ...Page 46 1 Installation ...
Page 53: ...Page 49 1 Installation ...
Page 55: ...Page 51 1 Installation ...
Page 58: ...Page 54 Turbo Boost 1 Installation ...
Page 59: ...Page 55 Set Efficiency Mode to 24 Hour 1 Installation ...
Page 60: ...Page 56 Set Efficiency Mode to Filtration Schedule 1 Installation ...
Page 61: ...Page 57 1 Installation ...
Page 63: ...Page 59 1 Installation ...
Page 65: ...Page 61 1 Installation ...
Page 84: ...Page 80 Model Number Example 3 Appendix ...
Page 89: ......
Page 144: ...Rev L 8 12 13 MASTERTEMP Pool and Spa Heater Installation and User s Guide 55 N TES ...