Page - 27
WARNING
Failure to heed the following may result in injury or death.
l
This section is only for qualified installers who are familiar with the swimming pool and spa safety standards.
l
The installer must be familiar with service industry techniques.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Do not use an electric heater connection on external controllers for
heat pump wiring.
This can cause damage to external controllers, heat
pumps, and pad equipment. This damage is NOT covered by warranty.
l
The wire size connecting the external controller to the heat pump must be 22-
gauge, 2-conductor, low-voltage wire.
l
Use the two middle data lines on the external controller's standard communication port (RS-485). Do not use the
outside power or ground connection on the port.
c.1 Connecting Smart Bus Controllers
External Controller
Communication Port
Wire Connections
1. Deactivate power to heat pump and external controller.
2. Remove electrical access panels on the heat pump and external controller.
3. Route 22-gauge, 2-conductor, low-voltage wires from the external controller
communication port (com port) to the low voltage side of the heat pump's electrical
enclosure. Do not use the power or ground wire.
Figure 1
4. Connect control wires to the heat pump's "Port B" of the
microprocessor as indicated. See
l
It is OK to double up wires at the external controller
connection if necessary.
l
If, for example, the external controller is using the data
port for an indoor controller, add wires to the existing
configuration.
Connectors can be removed from
terminals for ease in connecting wires. See Figure 3
1
-
Ins
ta
lla
tion
Summary of Contents for HeatWave SuperQuiet SQ120R
Page 2: ......
Page 28: ...Page 24 Configure Call Flex Enter Installer Menus then proceed 1 Installation ...
Page 33: ...Page 29 Configure for Smart Bus Controller Enter Installer Menus then proceed 1 Installation ...
Page 36: ...Page 32 Configure 2 wire controller Enter Installer Menus then proceed 1 Installation ...
Page 40: ...Page 36 1 Installation ...
Page 41: ...Page 37 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation ...
Page 42: ...Page 38 1 Installation ...
Page 45: ...Page 41 1 Installation ...
Page 47: ...Page 43 1 Installation ...
Page 50: ...Page 46 1 Installation ...
Page 53: ...Page 49 1 Installation ...
Page 55: ...Page 51 1 Installation ...
Page 58: ...Page 54 Turbo Boost 1 Installation ...
Page 59: ...Page 55 Set Efficiency Mode to 24 Hour 1 Installation ...
Page 60: ...Page 56 Set Efficiency Mode to Filtration Schedule 1 Installation ...
Page 61: ...Page 57 1 Installation ...
Page 63: ...Page 59 1 Installation ...
Page 65: ...Page 61 1 Installation ...
Page 84: ...Page 80 Model Number Example 3 Appendix ...
Page 89: ......
Page 144: ...Rev L 8 12 13 MASTERTEMP Pool and Spa Heater Installation and User s Guide 55 N TES ...