Part number 550-100-305/0916
80
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
— C
OMBI
Boiler Manual
32
Troubleshooting
(continued)
Figure 101
)NSTALLERMODE
Installer mode
By pressing the RESET push button for 20 seconds, it is possible to entered the Installer mode. During this time, the OTC mode
must not be entered. The display starts showing: “tS” flashing. By means of the CH+ and CH- push buttons it is possible to select
“tS” or “In” or “Hi” or “rE”. “tS” means “Transparent parameter”; “In” means “Inquiry”; “Hi” means “History”; “rE” means “Reset”.
By means of the Reset button (1 activation for 1 second) on “tS” it is possible to enter the “Transparent parameter” mode, on “In” it
is possible to enter the “Inquiry” mode, on “Hi” is possible to enter the “History” mode; by means of the ECO button (1 activation
for 3 seconds) on “rE” is possible to reset all the History information.
By pressing the DHW- and DHW+ push buttons together for 10 seconds, it is possible to leave the Installer mode. If no action has
been taken, the control automatically leaves this mode after 2 minutes.
tS
blinking
Transparent parameter mode
Do NOT change settings.
In
blinking
Inquiry mode
Hi
blinking
History mode
rE
blinking
Reset all the History information