Part number 550-100-305/0916
82
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
— C
OMBI
Boiler Manual
32
Troubleshooting
(continued)
t01
blinking
CH Supply sensor1 Temperature (°F)
between 32 and 257
t02
blinking
CH Supply sensor2 Temperature (°F)
between 32 and 257
t03
blinking
CH Return sensor Temperature (°F)
between 32 and 257
t04
blinking
DHW sensor Temperature (°F)
between 32 and 257
t05
blinking
Outdoor sensor Temperature (°F)
between -22 and 158, blinking if it is negative
t06
blinking
Exhaust sensor Temperature (°F)
between 32 and 257
F07
blinking
Actual Blower Speed (Hz)
;<_*'?'='_'<=;<
L08
blinking
Actual burner load (%)
;<QJ!|?@?_@?
F09
blinking
>?@&!?'!?'^&*;<`
between 00 and 255
P10
blinking
Actual water pressure (psi)
P11
blinking
Actual PWM modulating Pump (%)
;<
P12
blinking
Actual Step of Triac mod. mode (Num)
;<Q
F13
blinking
>?@& &*'z@'<?^@`
between 00 and 255
Figure 102
$EFAULT#ONTROL"OARDh4RANSPARENT0ARAMETERSv
Boiler
Model
“b01”
“b02”
“b04” “b05” “b06”
“b10” “b12”
“P01”
“P02”
“P04”
Gas type
Boiler
type
Blower Max.
Freq. in DHW
Blower Max.
Freq. in CH
Blower Min.
Freq. in CH
S/W mode
selection button
Var. Out
Relay
Ignition
level
CH Slope
(F/min)
CH
Off Time
WMB-155C N
$?
3
205
205
39
1
7
60
11
2
WMB-155C LP
X\j
3
200
200
40
1
7
60
11
2
“In” as Inquiry mode
Selecting “In” the display starts with showing “
T
” blinking. By means of the CH+ and CH- push buttons it is possible to select the
parameters; between “
T
” and “
F13
”. Selecting one of these parameters, by means of the DHW+ and DHW- push buttons is pos-
sible to see his value (not flashing; only in case of negative outdoor temperature the value is flashing).
Figure 103
h)Nv)NQUIRYMODE
s
In case of Water pressure switch: “00” means open, “20” means closed.
s
In case of sensors in short circuit or open circuit, the display visualizes: “--”.
s
Actual Blower Speed is showed always in terms of Hz.
s
Actual water flow rate is showed always in terms of real l/min *10 and it has to be visualized also with the input switch
contact open. Example: real 1.5 l/min has to be visualized as 15.
s
Actual Flame Current is showed always in terms of real uA*10. Example: real 0.3 uA*10 has to be visualized as 3.
s
In case of DHW thermostat, t04: “On” means closed, “OFF” means open.
By pressing the RESET push button for 1 second, it is possible to escape from the “Inquiry” mode. By pressing the RESET push
button for 20 seconds, it is possible to leave the Installer mode. If no action has been taken, the MMI automatically leaves this
mode after 15 minutes.