Figure 49
:ONEVALVEZONINGPRIMARYSECONDARY
CONNECTIONASYSTEMCIRCULATORISREQUIRED
,%'%.$FOR
Figure 49
.
.OTE
4HISISACOMMONLEGENDFORALLPIPINGDIAGRAMS.OTALL
ITEMSLISTEDAPPEARINEVERYlGURE
1
WMB-155C
wall mount boiler
2 Relief valve, supplied by Installer, field piped —
MUST be piped to boiler supply connection — see
page 9 for information
3 Isolation
valves
4 System
circulator
5 Expansion tank, diaphragm type, if used
6 Air
separator
7 Flow/check
valves
8 Purge/drain valves (Installer supplied)
9 Auto air vent
10 Zone valves
11 Primary/secondary connection (tees no more
than 12 inches apart)
12 Expansion tank, closed type, if used (some
chiller systems may use a diaphragm-type
expansion tank)
13 Water chiller
14 Check valve
15 Y-strainer
16 Balancing valve
17 Make-up water supply – Use applicable codes
to determine if backflow preventers, pressure
reducing valves, and fill valves may be required
18 By-pass pressure regulator, REQUIRED for zone
valve systems unless other provision is made
19 High limit temperature control
20 Zone circulator
21 Pressure/temperature gauge, supplied with boiler,
field piped
22 Heating circuits
23 Additional heating circuits, if any
24 Mixing valve, if any
Part number 550-100-305/0916
39
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
— C
OMBI
Boiler Manual
Zone Valve zoning – primary/
secondary
See Figure 49.
1. This configuration is for zone valve systems using a
boiler loop connected as a secondary circuit off of a
primary system loop. Systems whose flow characteristics
do not comply with those listed in Figure 47, page 37
must pipe the boiler loop as a secondary circuit as show.
2. Systems zoned with zone valves recommend use a by-
pass pressure regulator.
3. Install a system circulator (supplied by installer) capable
of delivering the proper flow and head as shown.
Expansion Tank required
1. Provide a system expansion tank following the guide-
lines on pages 36 or 37.
2.
DO NOT
use a closed-type tank if connecting to a boiler
that is equipped with an automatic vent.
Overriding the Outdoor Reset function by
connecting space heating zones to inputs and
outputs intended for DHW applications may
violate
Section 303 of the 2007 Energy Act.
See page 99 for compliance information and
exemptions.
Controlling the Zones
1.
The control can be used to control space heating only,
domestic water heating only, or both. Refer to field
wiring, beginning on page 47, for instructions on wiring
to zone valves.
2. The boiler and zone valves can also be operated by a
zone controller.
Connect zone valve end switches to HEAT
input. Connect system circulator to HEAT
Circ. output.
Use isolation relays if connecting 3-wire zone
valve end switches to the HEAT input.
17
Primary/Secondary System Piping
(continued)