Figure 64
#ONTROLPANEL
,%'%.$FOR
Figure 64
1
—
Domestic Hot Water temperature setpoint decreasing button
2
—
Domestic Hot Water temperature setpoint increasing button
3
—
Central Heating water temperature setpoint decreasing
button
4
—
Central Heating water temperature setpoint increasing button
5
—
LCD Display
6
—
Reset / OTC button
7
—
Economy-Comfort On-Off -Power button
8
—
Domestic Hot Water symbol
9
—
Domestic Hot Water mode operation
11
—
Multi-function indication (Flashing during heat
exchanger protection)
12
—
Economy symbol
13
—
Central Heating mode operation
14
—
Central Heating symbol
15
—
Burner on and actual load indication (Flashing during
flame current supervision)
16
—
Temperature-Pressure gauge
Part number 550-100-305/0916
50
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
— C
OMBI
Boiler Manual
24
Controls and operation
Control Introduction
This boiler is a high-efficiency condensing pre-mix appliance
for central heating and hot water production, running on
Natural gas or Liquefied Petroleum (Propane) gas, generating
extremely low emissions.
The boiler is constructed with a stainless steel heat exchanger
providing effective condensation of the water vapor contained
in the flue gases, permitting extremely high efficiency.
Inside the boiler there is a premix burner with a large stainless
steel surface.
The boiler is sealed from the installation room: the air needed
for combustion is drawn from outside. The boiler also includes a
gas valve, pump, safety valve, flow sensor, dual safety and control
temperature sensor, a safety thermostat and a low water pressure
switch.
Thanks to the microprocessor control and adjustment system
with advanced self-diagnosis, unit operation is for the most part
automatic. The system heating temperature is automatically
governed by the control system.
The display continuously provides information on the unit’s
operating status and it is easily possible to obtain and adjust
temperature set-points, etc. or configure them. Any operating
problems associated with the boiler are immediately signalled by
the display and, if possible, corrected automatically.