4 Converting boiler to propane
Prepare boiler for propane
(if
required)
Propane operation
!,,
boilers must be converted for
PROPANEOPERATION
.
Converting an existing natural gas-
lREDBOILERFORPROPANE
—
For a boiler
already installed, you must turn off gas supply,
turn off power and allow boiler to cool before
proceeding. You must also completely test the
boiler after conversion to verify performance
and start up the boiler following instructions
beginning on page 60 of this manual.
6ERIFY#ONVERSIONKIT
—See Figure 8.
LP gas venturi will have a black label and will
be clearly labeled “
GPL
”.
Natural gas venturi will have a white label
and will be clearly labeled “
.!4'!3
”.
Failure to comply could result in severe per-
sonal injury, death or substantial property
damage.
Figure 8
.ATURALAND,IQUElED0ETROLEUM0ROPANE
GASCONVERSIONKITS
Boiler Model
+IT0ART.UMBER
7-"#.'
640-000-082
7-"#,0
640-000-083
This conversion kit shall be installed by a qualified
service agency in accordance with the
manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these instructions
is not followed exactly, a fire, an explosion or
production of carbon monoxide may result causing
property damage, personal injury or loss of life.
The qualified service agency is responsible for the
proper installation of this kit. The installation is
not proper and complete until the operation of the
converted appliance is checked as specified in the
manufacturer’s instructions supplied with the kit.
s
Follow all instructions in proper order.
s
Do not tamper with venturi. DO NOT change or modify
venturi in any way.
s
Do not leave an uninstalled venturi in the building.
s
Caution the gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the conversion.
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and
dangerous operation.
7-"#,0
P/N 640-000-083 NG to LP Gas Conversion Kit contents:
Venturi - 16.6 LP Gas
1
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
Label Gas Conversion
1
Label WMB-155C Rating Plate Conversion LP
1
Instructions Conversion Natural to LP Gas
1
7-"#.'
P/N 640-000-082 LP to Natural Gas Conversion Kit contents:
Venturi - Natural Gas 16.6m
1
Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
Label Gas Conversion
1
Label WMB-155C Rating Plate Conversion NG
1
Instructions Conversion LP to Natural Gas
1
.ATURALTO,0#ONIT0ART.UMBERS
,0TO.ATURAL#ONIT0ART.UMBERS