CFS100 SERIES OPERATION MANUAL
SECTION 10: CALIBRATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS100 Series Power Source Operation Manual
Page 141 of 146 PN 160951-10
10.4.6
High & Low Power Range Calibration
Using the “
∧
,
∨
" soft keys, navigate to Power xx.xW, or Power xxxxW parameter and press
the “
Select
” soft key.
Follow the prompt message provided on the display, and press the “
Test/Reset
” button to
move into the calibration screen for wattage. If you press the “
Exit
” soft key at this screen
you return to the calibration mode screen.
Enter the power reading from the wattmeter with the numeric keypad. When the value has
been selected press the “
Enter
” soft key and you will be moved to the next calibration
parameter. The soft keys “
Volt+
” and “
Volt-
” are available, if needed, to adjust the voltage
output of the instrument to set a proper wattage value if a different load is used than called
out in this manual. If you press the “
Esc
” soft key you will be returned to the calibration
mode screen.