23
-
AT 80/E
SLIDING GATES
English
NOTES FOR USERS
6.
IMPORTANT
At regular intervals, we recommend carrying out regular
checks by specialised personnel to ensure that the
operator is running smoothly. Do this at least once every
12 months.
Emergency manouvre (release)
6.1
In the event of a blackout, release the operator (
Fig.22
) and
open the gate by hand:
open the plastic cover
•
(
ref.A
)
turn the key counterclockwise (
•
ref.B
)
open the release by turning completely the lever (
•
ref.C
)
Re-lock the operator, at the end of the manual operation
and turn the key clockwise. Slide the gate slightly in one
direction, until you hear a coupling click.
Allways the power supply must be disconnected, when
the operator is released.
Before to restore the mains power supply, it is necessary
to close the gate (closing limit switch engaged). If not, the
operator can have unexpected functioning in response to each
type of command (Step-by-Step START, remote control, etc.).
NOTES FOR MAINTENANCE TECHNICIANS
7.
IMPORTANT
Maintenance can only be carried out by specialised
personnel. Before servicing the operator use the differential
switch to disconnect the power supply.
For correct maintenance regularly carry out the following checks
as given in the maintenance manual issued by the installer.
Tab.3
operation
interval
Inspect the general condition of the gate
structure and the upper guides.
12 months
Inspect the condition of wheels, guide,
couplings and limit stops.
12 months
Inspect the condition of the safety devices
(photocells, ribs…) and the performance of
the electronic clutch.
12 months
Check that the electric system and differential
switch work correctly.
12 months
Check that the input of the Stop push-button
is connected to a NC contact and that it is
working correctly.
12 months
Aprimatic S.p.A.
via Leonardo da Vinci, 414
40059 Villa Fontana di Medicina - Bologna - Italia
Tel. +39 051 6960711 - fax +39 051 6960722
[email protected] - www.aprimatic.com
SPACE RESERVED FOR INSTALLER
PLEASE GIVE A COPY OF THIS PAGE TO THE USER
Troubleshooting
7.1
See Tab.4.
TYPE
OF
FAULT
PROBABLE
CAUSES
SOLUTIONS
THE
GATE
DOES
NOT
OPEN
WHEN
COMMANDNED
AND
THE
MOTOR
DOES
NOT
START
-
UP
.
NO
POWER
.
•
RESTORE
THE
VOLTAGE
.
•
T H E
C I R C U I T
I S
N O T
•
CORRECTLY
CONNECTED
.
CHECK
THAT
THE
CONTROL
•
U N I T
I S
C O R R E C T L Y
CONNECTED
,
THAT
IT
HAS
NOT
LOST
CONNECTIONS
.
THE
UNUSED
NC
CONTACT
HAVE
TO
BE
JUMPERED
.
IL
RADIO
-
CONTROLS
ARE
NOT
•
WORKING
.
C H E C K
T H AT
T H E
R A D I O
•
C O N T R O L
B A T T E R Y
I S
CHARGED
.
C H E C K
T H A T
T H E
•
TRANSMITTER
AND
RECEIVER
CODES
MATCH
.
CHECK
THAT
THE
RECEIVER
•
IS
WORKING
.
THE
CONTROL
UNIT
IS
NOT
•
WORKING
.
CHECK
THE
FUSES
.
•
CHECK
THE
OPERATING
LOGIC
•
SETTED
.
THE
LIMIT
SWITCH
IS
NOT
•
CORRECTLY
CONNECTED
OR
IS
FAULTY
.
C H E C K
T H AT
T H E
L I M I T
•
SWITCH
IS
CONNECTED
AND
WORKING
.
ON
GIVING
THE
OPENING
COMMAND
THE
MOTOR
STARTS
-
UP
BUT
THE
WING
DOES
NOT
MOVE
.
THE
RELEASE
IS
OPEN
.
•
CLOSE
THE
MANUAL
RELEASE
.
•
THE
CONNECTION
BETWEEN
•
MOTOR
AND
LIMIT
SWITCH
IS
INVERTED
;
THE
MOTOR
IS
PUSHING
THE
WING
IN
THE
OPPOSITE
DIRECTION
.
RESTORE
THE
CORRECT
LIMIT
•
SWITCH
CONNECTIONS
.
THE
CLUTCH
IS
LOOSE
.
•
SET
THE
TORQUE
.
•
THE
GATE
OPENS
IN
JERKS
,
IS
NOISY
OR
STOPS
HALFWAY
.
THE
RACK
IS
RESTING
ON
THE
•
PINION
OR
THE
BAR
PIECES
ARE
NOT
EVENLY
SPACED
.
CHECK
THE
RACK
AGAIN
AND
•
RESET
IT
TO
THE
CORRECT
POSITION
.
THE
GUIDE
HAS
STEPS
OR
THE
•
GATE
RESISTS
MOVEMENT
.
CHECK
THE
GUIDE
AND
WHEELS
•
A N D
I M P R O V E
S L I D I N G
.
THE
SENSITIVITY
OF
THE
•
CLUNCH
IS
NOT
CORRECT
.
ADJUST
THE
TORQUE
;
IF
THE
SAFETY
•
STANDARD
ARE
NOT
ASSURED
,
ADD
MORE
SAFETY
DEVICES
.
T H E
P O W E R
O F
T H E
•
GEARMOTOR
IS
INSUFFICIENT
FOR
THE
GATE
FEATURES
.
U S E
A
M O R E
P O W E R F U L
•
G E A R M O T O R
(
S E E
PA R
.
TECHNICAL
DATA
).
ON
GIVING
A
CLOSING
COMMAND
,
THE
GATE
DOES
NOT
CLOSE
.
T H E
P H O T O C E L L S
A R E
•
FAULTY
.
CHECK
PHOTOCELLS
AND
•
R E L E VA N T
C O N N E C T I O N S
(
SEE
THE
CONTROL
UNIT
).
THE
CONNECTIONS
ARE
NOT
•
CORRECT
R E S TO R E
T H E
C O R R E C T
•
CONNECTION
.
T H E
K E Y
R E L E A S E
O F F E R S
S T R O N G
R E S I S TA N C E
O R
I S
BLOCKED
.
ON
GIVING
THE
OPENING
COMMAND
THE
MOTOR
STARTS
-
UP
BUT
THE
GATE
DOES
NOT
MOVE
.
THE
WING
STOPS
AGAINST
•
T H E
M E C H A N I C A L
L I M I T
BEFORE
THE
WING
HAS
BEEN
AUTOMATICALLY
STOPPED
,
CAUSING
ON
LOAD
BLOCKING
OF
THE
GEARS
.
C O R R E C T
T H E
P L AT E S
•
POSITION
AND
THE
BRAKING
TIME
.
CHECK
THAT
THE
LIMIT
SWITCH
•
WORKS
CORRECTLY
.
Fig.22
C
B
A