Installation and Service Manual – Metered Carbon Filter
Page 17
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Table 6 – Settings Options Table
Volume
Capacity
Regeneration
Time Option
Days
Override
Result
Any
Number
NORMAL
OFF
Regeneration occurs at the next Regen Set Time when
volume capacity reaches 0.
(Also known as Meter Delay Demand Initiated Regeneration)
OFF NORMAL
Any
Number
Regeneration occurs at the next Regen Set Time when the
specified number of days between regenerations is reached.
(Also known as Time Clock Initiated Regeneration)
Recommended
(Default) Setting
Any
Number
NORMAL
Any
Number
Regeneration occurs at the next Regen Set Time when
volume capacity reaches 0 or the specified number of days
between regenerations is reached.
(Meter Delay Demand Initiated Regeneration with Days
Override)
Any
Number
On 0
OFF
Regeneration occurs immediately when volume capacity
reaches 0. Time of regeneration will not be allowed to be set
because regeneration will always occur immediately when
volume capacity reaches 0.
(Also known as Meter Immediate Demand Initiated
Regeneration)
Any
Number
NORMAL
+ On 0
Any
Number
Regeneration occurs at the next Regen Set Time when the
specified number of days between regenerations is reached
,
unless the gallons capacity reaches 0 before that time. If the
gallons capacity reaches 0, regeneration occurs after 10
minutes of no water usage.
Note: Reserve Capacity is not automatically estimated in Filtering applications. (Feature is available for softener
applications only.) To set a manual reserve capacity, set the gallons capacity to a number that is lower than the actual
estimated capacity of the system.