Design Basis & Specifications
Table 1 – Specifications
Model No.*
Flow Rate**
(GPM)
Backwash
Flow**
(GPM)
Volume of Media
(ft
3
)
Resin Tank
(Dia”×H”)
Valve
Size
In/Out
Conn.
5gpm/ft
2
15gpm/ft
2
Carbon
(Only)
Total
(Incl.
Underbed)
W-G744EM
1 4 2.2 0.50
0.60 7×44 1” 1”
W-G844EM
2 5 2.7 0.60
0.70 8×44 1” 1”
W-G940EM
2 6 3.2 0.75
0.85 9×40 1” 1”
W-G1054EM
2 7 4.2 1.25
1.45
10×54
1” 1”
W-G1252EM
4 12 6.5 1.75
2.05 12×52 1” 1”
W-G1354EM
4 14 7.5 2.00
2.30 13×54 1” 1”
W-G1465EM
5 16 7.5 3.00
3.50 14×65 1” 1”
W-G1665EM
7 21 15 3.50
4.00 16×65 1” 1”
*
Filters are available with USA or European style plugs and voltages. Please add the appropriate voltage code to the end of the
model no. when ordering.
120V AC/60Hz with USA plug = US -
Example: W-G744-US
**
Volume of Media is approximate and includes underbedding.
***
5 gpm per sq. ft. of media is the best design condition for filtration. For relatively clean water, you may go up to design
criteria of 15 gpm per sq. ft. Backwash flow rate based on 25 psi pressure drop.
Specifications
Vessel rated at 150 psi max. operating pressure, 120°F max. operating temp.
All Systems Automatic
General Information and Safety
DISCLAIMER:
The information contained in this document is subject to
change without notice. Applied Membranes, Inc. shall not
be liable for technical or editorial omissions made herein;
nor for incidental or consequential damages resulting from
the furnishing, performance, or use of this material.
READ THIS MANUAL:
Prior to operating or servicing this unit, this manual must be
read and understood. If anything is not clear, call for
assistance before proceeding. Keep this and other
associated manuals for future reference and for new
operators or qualified service personnel
.
USE PROPER POWER CONNECTIONS:
Use proper wiring and connection methods to satisfy local
electrical codes. SHOCK HAZARD: Connect this unit to a
properly grounded connection in accordance with the
National Electrical Code. DO NOT, under any
circumstances, remove the ground wire or ground prong
from any power plug. Do not use extension cords or an
adapter without proper consideration.
SERVICE WARNING:
To prevent electrical shock, disconnect power to the system
prior to servicing.
WARNING:
Do not make any alteration or modification in the wiring or
plumbing of the system. This can result in damage to the
system and cause injury to operators or users.
WARNING:
Flush the system for at least 30 minutes before use to
remove all chemicals present.
CAUTION:
Never let the carbon filter freeze. Freezing can damage the
resin tank.