Installation and Service Manual – Metered Carbon Filter
Page 18
Copyright © 2012 Applied Membranes, Inc. All Rights Reserved.
Installer Display Settings
STEP 1I
Press NEXT and
▲
simultaneously for 3 seconds to enter Installer Settings Screen.
STEP 2I
This display should show “–nA–”
Press NEXT to go to step 3I. Press REGEN to exit Installer Display Settings.
(If Hardness Grains appear as shown on the left, the valve is incorrectly set up as a
Softener: return to step 2F and refer to Filter System Setup instructions to correct.)
STEP 3I
Day Override: When gallon capacity is set to AUTO or to a number, Day Override
sets the maximum number of days between regenerations.
Recommended Setting
for Days Override = 12 Days.
If value set to “OFF” regeneration initiation is based
solely on gallons used. If value is set as a number (allowable range from 1 to 28) a
regeneration initiation will be called for on that day even if sufficient number of gallons
were not used to call for a regeneration. Set Day Override using
▼
or
▲
buttons:
number of days between regeneration (1 to 28); or
“OFF”.
When gallon capacity is set to off, the valve operates as a time clock valve and the
Day Override sets the number of days between regenerations.
See Setting Options Table for more detail on setup.
Press NEXT to go to step 4I. Press REGEN to return to previous step.
STEP 4I
Next Regeneration Time* (hour): Set the hour of day for regeneration using
▼
or
▲
buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This display will show
“REGEN on 0 GAL” if “on 0” is selected in Step 7F.
Press NEXT to go to step 5I. Press REGEN to return to previous step.
STEP 5I
Next Regeneration Time* (minutes): Set the minutes of day for regeneration using
▼
or
▲
buttons. This display will not be shown if “on 0” is selected in Step 7F. Press
NEXT to exit Installer Display Settings. Press REGEN to return to previous step.
* Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when
a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.