Valve History
For all steps below: Press the NEXT button to proceed to the next step. Press REGEN to return to previous step or exit.
STEP 1VH
Press
▲
and
▼
simultaneously for three seconds and release. Then press
▲
and
▼
simultaneously and release. If screen in step 2VH does not appear in 5 seconds the
lock on the valve is activated. To unlock press
▼
, NEXT,
▲
, and SET CLOCK in
sequence, then press
▲
and
▼
simultaneously for 3 seconds and release. Then press
▲
and
▼
simultaneously and release.
STEP 2VH
Software Version: This display shows the software version of the valve. Press the
NEXT button to go to Step 3VH. Press REGEN to exit Valve History.
STEP 3VH
Flow rate, maximum since startup: This display shows the maximum flow rate in
gallons per minute that has occurred since startup.
STEP 4VH
Gallons, total used since start-up: This display shows the total gallons treated since
startup.
STEP 5VH
Days, total since start-up: This display shows the total days since startup.
STEP 6VH
Regenerations, total number since start-up: This display shows the total number of
regenerations that have occurred since startup.
STEP 7VH
Error Log: This display shows a history of the last 10 errors generated by the control
during operation. Press the
▲
or
▼
buttons to review each error recorded. Press the
NEXT button to exit Valve History.
Note: Values in steps 3VH through