25
Figure 3.21 Com1 setup-TCP server
Note
:
1. Default Port number of STE-501C is 4660 and it is associated with serial port COM1 respectively. After
ones application program connects to the TCP port 4660 of STE-501C, data being sent to this TCP
connection from ones application program are transparent to the COM1 of STE-501C. Vice versa is
also true.
2. The serial interface will show different port interface according to the model of the serial server.
3.3.5 Configure STE-501C as TCP Client
Configure STE-501C as TCP client, for example the destination IP is 10.0.29.11, destination port is
4660 .( Figure 3.22)
Input destination IP “
10.0.29.11
”
Input destination port in the “
4660
”
Input idle time in “
Please input idle time to send TCP alive packet ( sec)
:
”(If one input
4
->the
sending TCP keep alive packet period will be change to 4*10 sec)
1.
Select “
TCP Connect On Power-on
”
:
to keep trying to establish TCP connection after Power on
2.
Select “
TCP Connect On Any Serial Character
”
:
Any serial character will trigger to establish the TCP
connection
Input idle time to disconnect in the “
Serial Inactivity Time before disconnect(0sec , 1~255)
:
” (If one
input
0
->disable the function; if one input
2
->the serial Inactivity beyond 2 sec will cause disconnect)
Input error retrying time in “
Waiting Time Between Re-connect Attempts(0 minute,1~255)
:
” (If one
input
0
->disable the function; if one input
2
->the serial Inactivity beyond 2 sec will cause disconnect)
Click on “
Save Configuration
” button to save the changes