6-10 Removal Procedures
Assemblies Removal and Replacement
6-14
PN: 10370-10386 Rev. B
MG362x1A MM
Remove the Covers
Use this procedure to remove the covers.
Tools Required
•
# 1 Phillips screwdriver
Preliminary
Disconnect the power cord from the instrument. Refer to the following procedures:
•
“Remove the Handles” on page 6-12
•
“Remove the Rear Feet” on page 6-13
Procedure
Refer to
1.
Remove the M3X5 screws (x4) that retain each cover from the rear panel. Retain the screws to use when
reinstalling the covers.
2.
Pull each cover away from the lip of the front bezel to remove.
3.
Installation is performed in reverse order.
1. Flange Under Lip of Bezel
2. Top Cover
3. Vented Side Cover
4. M3X5 Screw (x4)
5. Bottom Cover
6. Non-Vented Side Cover
Figure 6-9.
Remove Covers
1
3
5
6
4
2