7-5
Use with a HP8757D
Scalar Network
Analyzer
The MG369XB signal generator is compatible with the Hewlett
Packard Model 8757D Scalar Network Analyzer (SNA). The following
paragraphs provide instructions for connecting the MG369XB to the
HP8757D SNA and setting up the signal generator so that it can oper-
ate as a signal source for the analyzer. Operating instructions for the
scalar network analyzer can be found in the Hewlett Packard 8757D
Scalar Network Analyzer Operation Manual.
Connecting
the MG369XB
to a HP8757D
Connect the MG369XB signal generator to the
HP8757D scalar network analyzer as shown in Fig-
ure 7-4.
Step 1.
Connect one end of a GPIB cable to the
MG369XB rear panel
IEEE-488 GPIB
con-
nector. Connect the other end to the
HP8757D rear panel
8757 SYSTEM IN-
TERFACE
connector.
Step 2.
Connect one end of a coaxial cable having
BNC connectors to the MG369XB rear
panel
PULSE TRIGGER IN
connector.
Connect the other end of the cable to the
HP8757D rear panel
MODULATOR DRIVE
connector. (Required for ac mode detec-
tion)
Use With Other Instruments
Use with a HP8757D Scalar Network Analyzer
MG369XB OM
7-15
S W E E P I N 0 - 1 0 V
A U X
I / O
S E Q S Y N C
S W P D W E L L I N
S T O P S W E E P
C
A
B
R
M G 3 6 9 X B
S i g n a l G e n e r a t o r
H P 8 7 5 7 D S c a l a r
N e t w o r k A n a l y z e r
S e n s o r
8 7 5 7
S y s t e m I n t e r f a c e
M O D U L A T O R D R I V E
P O S Z B L A N K
H O R I Z O U T
P U L S E T R I G G E R I N
I E E E - 4 8 8
G P I B
T o D U T
T o D U T
Figure 7-4.
MG369XB to HP8757D SNA Connections
Summary of Contents for MG369 Series
Page 3: ......
Page 4: ......
Page 14: ...1 2 MG369XB OM Figure 1 1 Series MG369XB Synthesized Signal Generator ...
Page 20: ......
Page 22: ......
Page 38: ......
Page 154: ......
Page 156: ......
Page 158: ......
Page 174: ......
Page 214: ......
Page 216: ......
Page 230: ......
Page 232: ......
Page 260: ......
Page 262: ......
Page 268: ......