Selecting a
List Sweep
Trigger
There are four modes of sweep triggering in list
sweep frequency mode, each selectable from the trig-
ger menu. The following is a description of each
mode.
q
Auto (Automatic)—The output sweeps
between the specified list start and stop
indexes, dwelling at each list index for the
specified dwell time
q
External—The output sweep recurs when
triggered by an external TTL-compatible clock
pulse to the rear panel AUX I/O connector
q
Single (Trig)—A single output sweep starts
when the trigger key is pressed. If a sweep is
in progress when the key is pressed, it aborts
and resets
q
Manual—(list sweep default trigger mode) The
list index is incremented or decremented by
using the front panel cursor control keys. The
list index can also be incremented using an ex-
ternal trigger input. Each trigger increments
the list index by one
To access the List Sweep Trigger menu (below) from
the Sweep menu, press
Trigger >
.
To select a sweep trigger mode, press its menu
soft-key.
q
Press
Auto [AUT]
to select automatic trigger-
ing
q
Press
External [HWT]
to select external trig-
gering
q
Press
Single [EXT]
to select single sweep trig-
gering
q
Press
Manual [MNT]
to select manual trigger-
ing
MG369XB OM
3-49
Local (Front Panel) Operation
Sweep Frequency Operation
Summary of Contents for MG369 Series
Page 3: ......
Page 4: ......
Page 14: ...1 2 MG369XB OM Figure 1 1 Series MG369XB Synthesized Signal Generator ...
Page 20: ......
Page 22: ......
Page 38: ......
Page 154: ......
Page 156: ......
Page 158: ......
Page 174: ......
Page 214: ......
Page 216: ......
Page 230: ......
Page 232: ......
Page 260: ......
Page 262: ......
Page 268: ......