![AND Multi Function Weighing Indicator AD-4402 Instruction Manual Download Page 96](http://html.mh-extra.com/html/and/multi-function-weighing-indicator-ad-4402/multi-function-weighing-indicator-ad-4402_instruction-manual_2941316096.webp)
Page
94
AD-4402
8.8.
8.8.
8.8.
8.8.
Parallel I/O of Option OP
Parallel I/O of Option OP
Parallel I/O of Option OP
Parallel I/O of Option OP----05
05
05
05
Use this option to extend the I/O terminals
The function, settings, interface circuit and timing chart of the option is the same as
the built-in I/O terminal.
Input control
Contact to common
Input open voltage
7 ~ 11 V DC
Input current
5 mA max.
Input threshold voltage
2 V max.
Output circuit
Open collector transistor
Output voltage
40 V DC max.
Output saturation voltage
1.5 V at 50 mA
Connection
A1 ~ A16
Input terminals
A17
A18
A19
Input common
A20 Frame
ground
B1 ~ B16
Output terminals
B17
B18
B19
Output common
B20 Frame
ground
Terminal List
Refer to "10.4. Parameter List" of the function list.
Caution
Do not assign the same function to multiple input terminals and keys.
A20
B1
B20
A1