AD-4402 Page
119
Category
address
symbol
Name Descriptions
Range
and
choices
Default
5q f-39
Discharge
monitoring timer
Set the time limit to discarge it
When time is up and displayed value is
not zero band, sequence error
SQ.ERR5
is displayed.
If 0 is set, the timer does not work.
0 to
65535
s
0
s
5q f-40
Discharge gate
close delay timer
Set the waiting time from reaching to
zero band to closing discharge gate for
gross.
0.1 to
25.5
s
0.1
s
5q f-43
Batch finish output
on
Set the active (ON) time of the batch
finish signal. If 0 is set, output is kept
until next sequence.
0.00 to
2.55
s
0.00
s
5q f-44
Discharge finish
output on
Set the active (ON) time of the ON for
the discharge signal.
0.00 to
2.55
s
0.00
s
5q f-45
Recipe finish output
on
Set the active (ON) time of the ON for
the recipe finish signal.
0.00 to
2.55
s
0.00
s
5q f-46
Mixing finish output
on
Set the active (ON) time of the ON for
the mixing finish signal.
0.00 to
2.55
s
0.00
s
5q f-47
Mixing time output
on
Set the active (ON) time of the ON for
the mixing time signal.
0 to
255
s
0
s
5q f-48
Averaging Eval time
Set the time to average the result. This
time controls precision of the result.
Refer to
Eval delay timer
[
5q
f-37
] and
Eval conditions
[
5q
f-13
].
00.0 to
2.55
s
0.00
s
s
:
second
d