AD-4402 Page
9
TARE ENT
Tare entered.
With the tare value stored, this sign is illuminated.
HOLD
With the main display held, this sign is illuminated.
CZ
Center of zero.
When the gross weight is in the center of the zero point, this sign is
illuminated.
ZR.ERR
Zero error.
Error message for zeroing the gross data of the main display.
SQ.ERR
The sequence error sign.
Indicates a weighing sequence error.
ALARM 1
An error sign for over load or emergency stop mode.
ALARM 2
A fatal error sign. Example: The wire from the loadcell is broken.
Standby indicator
In the standby mode, all interfaces are turned off and only the
internal circuits work.
FULL
When the gross data exceeds the full limit, this sign is illuminated.
Z. BAND
The zero band sign.
When the gross data is within the range of the zero band (around
the zero point), this sign is illuminated.
F.FLOW
The full flow gate sign.
M.FLOW
The medium flow gate sign.
D.FLOW
The dribble flow gate sign.
FINISH