![AND Multi Function Weighing Indicator AD-4402 Instruction Manual Download Page 60](http://html.mh-extra.com/html/and/multi-function-weighing-indicator-ad-4402/multi-function-weighing-indicator-ad-4402_instruction-manual_2941316060.webp)
Page
58
AD-4402
7.3.13.
7.3.13.
7.3.13.
7.3.13.
Automatic Fre
Automatic Fre
Automatic Fre
Automatic Free Fall Compensation
e Fall Compensation
e Fall Compensation
e Fall Compensation
This function arranges the free fall parameter using the average of the last four
displayed values so as to get a more precise weighing.
Concerning Parameters of the Function
Using the automatic free fall compensation
[
5q f-20
] [
1
]
Average of last 4 FFalls
(free falls)
[Function] - [Function setting] - [Sequence] - [Control] - [Free fall
compensation]
Using the automatic free fall effective bandwidth
[Function] - [Function setting] - [MatEDIT] - [Code No.] - [AFFC range]
Refer to section 6.1.5.Editing Full Parameters of Material Code.
Using the manual free fall
[
5q f-20
] [
0
]
No
(Not used)
When using the signal from the I/O terminal to control free fall, use this.
[Function] - [Function setting] - [Sequence] - [Control] - [Free fall
compensation]
Storing the results of the automatic free fall compensation of each material.
[
5q f- 9
] [
1
]
Change FFall
When using the flash memory, set to [
0tHf-11
] [
2
].
[Function] - [Function setting] - [Sequence] - [Basic] - [Material code, free
fall value]
Advise
When the automatic free fall compensation can not work.
Check the flux of dribble flow.
When the error (| result - final value |) of displayed value is greater than this
parameter, the function does not work.
Check that the dribble flow timer is to short.
When the timer is shorter than
Dflow auto-FFall override
[
5q f-36
], the
function does not work.
When the accuracy does not improve, even if automatic free fall compensation is
used.
Check the stability of the dribble flow.
When the dribble flow is unstable and the dribble flow timer is shorter, the function
can not work correctly.
When the result becomes over, even if automatic free fall compensation is used.
Remove between preliminary and free fall
When the value of preliminary and free fall are near, medium flow only works to
reach the final value and the dribble flow can not work.