Selection of Batch Weighing
Selection of Batch Weighing
Selection of Batch Weighing
Selection of Batch Weighing
Selection of Normal Batching or Loss-in-weigh
The mode can be selected at
Loss-in-weigh
in the Function list.
([Function] - [Function setting] - [Sequence] - [Basic] - [Current weighing])
[
5q f- 3
] [
0
]
Normal batch weighing
[
5q f- 3
] [
1
] Loss-in-weigh
[
5q f- 3
] [
2
]
External selection (Normal batch weighing or Loss-in-weigh)
External Selection (Normal batch weighing or Loss-in-weigh)
Normal batch weighing and Loss-in-weigh can be selected by a signal at the input
terminal that is set to [
9
] of
External switch control
.
(The menu [Function] - [Function setting] - [Control I/O Function] - [Input] )
Example of use: 100 kg of material is supplied to the hopper in the first step. It is
subdivided into material of 10 kg.
Advise
If the mode is switched concerning a specified material only, set the hopper no. in the
material code, short the hopper no. output line and the supply/discharge switch input
line. Set the delay timer [
5q f-32