Copyright © 2015 Shenzhen ANB Technology Co., Ltd. All rights reserved.
Factory defaults setting are as following:
1
Time-based Data Report Interval: 60Seconds
2
Distance-based Data Report Interval: 500Meters
3
Angle-based Data Report Interval: 30Degrees
4
ACC ON/Off Report: ON
5
IP,Port, APN, username and password: Empty
6
Authorized Numbers A/B/C/D/G: Empty
7
Default Password: 1234
8
GEO Fencing Areas: Empty
9
Speed Over Limit: 0 ( Off)
10
Data Report when ACC Off: Off
11
Memory Records time interval: 5Minutes
12
Towing Alarm: ON
13
Buzzer Sound: Off
14
Incoming Call auto pickup: Off
15
Working Mode: SMS+GPRS
16
SMS Data Time: GMT Time
17
Sleep mode when ACC Off: Simple Sleep
-
Device will reboot itself after this command applied.
7.1.6 Setup Speed over Limit value:
Function
SMS Command Format
Device Reply SMS
Setup Speed limit Value
*UPWD*SPDxxx#
Speed Over alert activated: xxx Km/H
Example Command:
*1234*SPD080#
Example Reply:
Speed Over alert activated: 080Km/H
Note:
-
Xxx value range from 000-999.
-
Xxx=000 means cancel speed over alert.
7.1.7 Setup SMS Report Data time:
Function
SMS Command Format
Device Reply SMS
Setup SMS data time
*UPWD*GMT+/-XXXX#
GMTxxxx setup ok!
Example Command:
*1234*GMT+0830#
Which means the local time is earlier than GMT time with 8hours and 30Minutes
Example Reply:
GMT+0830 setup OK!