6. THREAD PICK-UP ADJUSTMENT
If the thread is not caught and held after trimming it is necessary to adjust the thread pick-up.
1. The machine must be in the home position.
2. Disconnect the air tubes of the thread puller.
3. Loosen the screws
1
,
2
,
3
.
4. Manually extend the cylinder
4
.
5. Adjust the thread puller position to obtain the distance 2 mm between the needle tip and the thread puller and
at the same time to have the needle in the centre of the thread puller slot. Tighten the screw
3
.
6. Move the thread puller assembly so that the distance between the needle and the end of the slot is approximately
1 mm. Tighten the screws
1
,
2
.