1-30
S-4001 ISBH+I SM 30°
Released: 09/2017
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
E - STANDARD MACHINE ADJUSTMENT
1. MACHINE HOME POSITION
1. The needle bar is in the upper position. The needle
1
descends to the right side of the throat plate slot
2
during
the first stitch. The marks
8
on the handwheel and cover
casting are aligned.
2. The clamp plate
3
with clamp feet
4
is in the full forward
position. The clamp plate moves to the rear during the first
row of stitching.
2. MAIN CAM ADJUSTMENT
1. Tilt the machine on the rest pin and view the main cam assembly.
2. Initial setting is the following: Set the left shifter arm
6
maximum left and right shifter arm
7
maximum right.
3. Further setting shall be done according to
section E9
.