1-58
S-4001 ISBH+I SM 30°
F - INDEXER - ANGLE 30°
Released: 09/2017
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
Software
correction of X, Y
home position
4. HOME POSITION ADJUSTMENT
4.1.
Indexer Clamp-feet Adjustment – Axis Y
a) Activate the indexer from the touch-screen panel by pressing the button
.
b) Check the sewing length matches the parameter set on the machine touch-screen panel, refer to the chapter E11
c) Check the sewing density matches the parameter set on the machine touch-screen panel, refer to the chapter E8.
4.2.
Indexer Clamp-feet Adjustment – Axis X
a) By pressing the buttons
check the distances X1, X2 between
the indexer clamp-feet and edge of the slot in the stainless cover-plate
are equal. If this is not the case, do the following:
- loosen the sensor nut and move the sensor to the desired position, loosen
the nut again; check the clearance between the sensor and the plate it
detects to be approx. 0.3 mm
- by pressing the buttons
check the correct adjustment
NOTICE:
Fine position changes can be adjusted from the machine touch-screen panel:
d) By pressing the buttons
move the indexer clamp-feet to the
rightmost position (left indexer foot is close to the sewing head clamp-
feet), adjust the angle to 0°.
e) Check the indexer clamp-foot is parallel to the edge of the slot in the
stainless cover-plate. If it is not the case, do the following:
- remove the indexer cover
- loose the sensor nut and move the sensor to the desired position, tighten
the nut again; check the clearance between the sensor and the plate it
detects to be approx. 0.3 mm
- by pressing the buttons
check the correct
adjustment
- mount the indexer cover again