S-311
1-46
Released:01/2014
E-mail: [email protected]; webside: amfreece.com
Phone: +420 582 309 146; Fax: +420 582 360 606
E - STANDARD MACHINE ADJUSTMENT
6. MECHANISM ADJUSTMENT FOR MATERIAL CLAMPING
WARNING!
Before doing any adjustments, disconnect the
air supply and deflate the test of compressed air in the
machine.
The basic clamp plates adjustment
1
with clamp feet
2
is
possible to modify after removing from the machine.
6.1. After loosening the screws
3
adjust the clamp feet
2
from front to rear (in the Y axis) and after loosening the
screws
5
from left to right (in the X axis)
6.2. The adjust feet
2
clamp against the plates
9
for 1,2
- 2,0mm overlap.
6.3. Remove the side table covers
6
by removing the
screws
7
.
6.4. Insert the clamp plates
1
into the machine.
6.5. Adjust the plates lift
2
for 12mm and after loosing the
screws
4
tighten them again.
6.6. Put the side table covers
6
on and screw them.
6.7. Check the proper adjustment when sewing.
Recommended space between the clamp foot and needle
during the outer penetration is 1 mm. If the bite size is
changed, ensure this space by covering the clamp feet
2
over clamp plate
9
- measure
A
to values. Adjust after
loosening the screw
5
and shifting the clamp plate arm to
the correct needed clearance.
Asymmetrical clamp