User Manual
AMETEK Programmable Power
RS Series
203
9.6.1 Option –704: MIL-STD-704 rev D & E Tests. (Firmware)
9.6.1.1 General
The MIL704 option is capable of performing most sections of MIL-STD-704 rev D and E in either
of the AC or DC mode.
Note: The Distortion Spectrum tests:
Table I and II, Figure 7
Table III, Figure 12
Table IV, Figure 18
are not supported by the –704 option. These tests require the use of additional
external equipment.
9.6.1.2 Initial Setup
Nominal parameters for the AC Power source are as follows:
Output Voltage
115V L-N
Output Frequency
400 Hz
Nominal parameters for the DC Power source are as follows:
Output Voltage
28V or 270V L-N
A setting outside these nominal values will disable the test and will prevent access to its Menu
screens.
9.6.1.3 Revision
The MIL704 option defaults to Revision E. The System is capable of performing
Revision D test by changing the selection to Revision D. All Revision D tests can be performed
except for the 270V DC TRANSIENT and ABNORMAL. For these tests, Revision E test levels
are used despite the revision D selection.
All levels and timing in this document refers to Revision E. For Revision D, refer to MIL-
STD-704D date 9/30/1980
9.6.1.4 Tests Performed
9.6.1.4.1 STEADY STATE
AC Mode:
1. Steady State Voltage and Frequency test
2. Waveform Distortion test
3. Voltage Modulation test
4. Voltage Unbalance test
5. Phase Unbalance test
6. Frequency Modulation test
7. Transient Voltage low and high test
8. Transient Frequency low and high test
DC Mode:
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...