User Manual
AMETEK Programmable Power
RS Series
62
4.1.3 Status Indicator Lights
Four LED status indicators are located directly above the mains circuit breaker. These LED’s
correspond to the following conditions:
REMOTE
The REMOTE LED indicates that the unit is in remote control
mode. If the IEEE-488 interface is used, this indicator will be lit
whenever the REM line (REMOTE ENABLE) line is asserted by
the IEEE controller. If the RS232, USB or LAN interface is used,
the REMOTE state can be enabled by the controller using the
SYST:REM command. Any time the REMOTE LED is lit, the
front panel of the RS Series unit is disabled. There is no LOCAL
button that allows the user to regain control of the front panel.
This prevents accidental change of settings in ATE applications.
OVERLOAD
The OVERLOAD LED indicates an output overload condition.
This condition can be controlled by setting the current limit
value in the PROGRAM menu. Removing the load using the
OUTPUT ON/OFF button will recover from an overload
condition.
OVER TEMPERATURE
The OVER TEMPERATURE LED indicates an overheating
problem inside the unit. This is an abnormal condition, which
will cause the unit to shut off. Check the air openings to make
sure they are not blocked.
HI RANGE
The HI RANGE LED is on when the high voltage output range
has been selected.
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...