Figure 9-2: DO160 Main Menu
9.3.1.5 AC TESTS
Note: Prior to test selection the standard and the group selection are required. Use the shuttle to
select the standard and the group if applicable.
9.3.1.5.1 Normal state test
Scroll to the NORMAL STATE AC entry using the up and down cursor keys. Press the ENTER
key to select the NORMAL STATE screens. The screen will appear as shown in Figure 9-3.
Figure 9-3: Normal State
The DO160 NORMAL 1 and NORMAL 2 screens have the following tests:
1
VOLT FREQ MIN
2
VOLT FREQ MAX
3
VOLT UNBALANCE
4
WAVEFORM DISTORTION
5
VOLT MODULATION
6
FREQ MODULATION
7
POWER INTERRUPT
8
VOLTAGE SURGE
9
FREQ TRANSIENT (group 1)
FREQ VARIATION (group 2 & 3)
The above tests can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test. For some of these tests, numeric data entry
may be required to define the test number or the modulation rate.
VOLT FREQ MIN
Standard/Group
RTCA
Group1
Group2
Group3
Voltage
1
100
104
104
104
3
101.5
105.5
105.5
105.5
Frequency
380
390
360
360
Table 9-1: Normal Voltage and Frequency Minimum
Standard/Group
RTCA
Group1
Group2
Group3
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...