Airbus AMD24C Test software (refer to Avionics Software Manual P/N 4994-
971 for details)..
Note: Requires use of RSGui Windows application software provided on CD
ROM CIC496.
-B787
Boeing 787 Test software (refer to Avionics Software Manual P/N 4994-971 for
details)..
Note: Requires use of RSGui Windows application software provided on CD
ROM CIC496.
-WHM
Watt Hour Measurements (Accuracy and Resolution. See Sec. 2.6.3.)
Output Voltage Range Options
- HV
Adds 400 V AC only output range.
- XV
Adds customer specified AC only output range. Contact factory for details.
Misc. Options
-ES
Emergency Shut off switch. This option key lock push button is installed on the
front panel of the master RS if ordered with the RS system. When pushed in,
the main AC contactor is opened disconnecting the AC input power to the RS
input transformer. Note that the controller (and LCD display) will still be
powered up but no power is available to the amplifiers and there will be no
output power either. The controller runs off the LV supply, which must be
turned off with the front panel breaker.
After the ES has been pushed, the provided key will be required to release it.
Once the ES button has been released, the RS
must
be powered down using
the front panel circuit breaker and turned back on to start up again.
Note: For multibox RS Systems (RS180 and up with more than one controller
and front panel controls, each of which having an ES emergency switch, to
connect a BNC cable between the cabinets for the ES connection. For 3 or
more cabinets with controller, this BNC can be daisy chained using BNC T
connectors.
Note: Do not misplace the 2 keys provided, as no duplicates are available from
CI. If lost, the ES switch must be replaced. In that case, contact AMETEK
Programmable Power customer service. (
).
-HF
Increases maximum output frequency to 905 Hz.
Note: This option cannot be combined with –LKM or -LKS option.
-LAN
Adds Ethernet interface (RJ45 connector) for local area network connection..
-LF
Limits maximum output frequency to 500 Hz.
-LKM
Clock and Lock system, Master. (Not available with –HF option)
-LKS
Clock and Lock system, Auxiliary. (Not available with –HF option)
-MB
Multi-box Option. Provides additional controllers in Auxiliary units of multi-
cabinet configurations to allow individual RS90 units to be used stand-alone.
-SNK
Current Sink Option. Allows application of regenerative loads that feed energy
(current, power) back into the RS output stage. The energy fed back is
returned to the AC line (utility) feeding the RS.
-FC
Frequency control option. When enable, will cause the frequency to step
±0.25% around the program value.
External Accessories (External to RS chassis)
7003-416-1
Input / Output wiring junction box. Connects two to six three-phase RS90
cabinet outputs, neutral and ground to a common output terminal block housed
in a metal enclosure junction box. Can also be used to connect multiple RS
chassis to common AC input service. See section 3.12 for details.
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...