User Manual
AMETEK Programmable Power
RS Series
196
IINTERHARMONICS GROUP
If the Harmonics group is selected, the screen will appear as shown in Figure 9-26. The screen
has the following parameters that are unique to the group:
Figure 9-26: IEC 1000-4-13 INTERHARMONICS
1. LEVEL
Sets the percentage level of the inter harmonics relative to the fundamental.
The level is fixed for the entire frequency range defined by FRANGE. To
change levels, the test state must be off and user class must be selected.
2. FRANGE
The range is selected by rotating the shuttle. The range selection is required to
change the level. An individual range step can be run by selecting the desired
range, followed by RUN RANGE from the RUN field.
3. STEP
The step size defines the inter harmonics sweep points. This step size is fixed
for the entire range of the sweep. The STEP size can be changed when the
test state is off.
4. IHFREQ
This field shows the current inter harmonic frequency when the test is running.
An inter harmonic frequency can be selected with the shuttle. To run an inter
harmonic frequency without sweeping through the entire range, RUN POINT
must be selected.
5. PAUSE
Sets the time in seconds for which the test will pause between inter harmonic
frequencies. There is only one value for the entire test. The PAUSE can be set
when the test is not running.
MEISTER CURVE GROUP
If the Meister curve group is selected, the screen will appear as shown in Figure 9-27. The
screen has the following parameters that are unique to the group:
Figure 9-27: IEC 61000-4-13 Meister Curve
1.
LEVEL
Sets the percentage level of the inter harmonics relative to the
fundamental. The level is fixed for the entire frequency range defined by FRANGE. To
change levels, the test state must be off and user class must be selected.
2.
FRANGE
The range is selected by rotating the shuttle. The range selection is
required to change the level. An individual range step can be run by selecting the
desired range, followed by RUN RANGE from the RUN field.
3.
STEP
The step size defines the inter harmonics sweep points. This step size is
fixed for the entire range of the sweep. The STEP size can be changed when the test
state is off.
4.
PAUSE
Sets the time in seconds for which the test will pause between ranges.
There is only one value for the entire test. The PAUSE can be set when the test is not
running. For the Meister curve test, the pause time is normally set to 0 secs. If a value
other than 0 is entered, the inter harmonics are set to 0% during the pause times.
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...