4.2.8 ADVANCE MEAS. Menu
This entry in the MENU 2 screen displays the HARMONICS/TRACE ANALYSIS screen which is
covered in section 4.6. This field can be used in lieu of the MEAS key to directly bring up the
advanced measurements screens.
4.2.9 APPLICATIONS Menus
Figure 4-18: APPLICATIONS Menus
The APPLICATIONS menu provides access to the optional application specific pre-programmed
test sequences. Since these test sequences are optional, this menu may have no choices if
none of the options are installed. The following entries may be found in the APPLICATIONS
menu:
Entry
Description
MIL-STD 704
Test sequence for MIL standard 704 AC and DC tests.
OMNI OPTION
This entry selects the OMNI control menu. The OMNI option
provides a lumped reference impedance for use in IEC 61000-
3-3 or IEC 61000-3-11 Flicker test applications. If the OMNI
option is installed, this screen allows the impedance to be
ENGAGED or BYPASSED.
RTCA/DO-160
Test sequence for RTCA DO160 commercial aviation AC and
DC tests.
IEC-1000-4-11
Test sequences for IEC 61000-4-11 Voltage Dips and
Variations test standard.
IEC-1000-4-13
Test sequence for IEC 61000-4-13 Harmonics and Inter
harmonics test standard.
WH METER
Watt Hour meter measurement option. Tracks energy usage
over a period of time and calculates Watt Hours used.
REGENERATE
The REGENERATE entry is enabled only if the –SNK option is
installed. It provides access to the setting for driving
regenerative load.
Summary of Contents for RS180-3Pi
Page 1: ...M440036 01 Rev G www programmablepower com RS Series AC and DC Power Source User Manual...
Page 58: ...User Manual AMETEK Programmable Power RS Series 58 Figure 3 14 Functional Test Setup...
Page 133: ...RS Series 133 Figure 5 3 Power Module Detailed Block Diagram...
Page 173: ...User Manual AMETEK Programmable Power RS Series 173 Figure 9 4 Voltage Modulation...