Defining Automatic System Functions
4-13
4.
Press the appropriate button—zoom or focus—to select
Alarm
Actions
.
The information for that camera's first alarm input appears on the LCD.
When you set up an alarm, you will indicate which Quick View, Pattern,
or fixed shot will be called up when the alarm is triggered. You will also
indicate which output initiates when this alarm is triggered. The video
action and the output must be associated with the same dome.
A sample setup alarm LCD is shown here.
Cam12/1 => Cam7
View96 Out3
If an alarm input has not been set up yet, the fields will have dashes in
them. A setup alarm LCD contains the following information:
Cam12/1 => Cam7
View96 Out3
In this sample alarm, input 1 on camera 12 is the specific input that will
trigger the alarm. The alarm input, for example, could be a motion
detector that triggers an alarm when it senses motion. When this alarm is
triggered, Quick View 96 on camera 7 appears on the monitor. In
addition, output 3 on the same camera initiates automatically. The output
might be, for example, a light that turns on when the alarm is triggered.
1
2
3
4
This is the specific Quick View
or Pattern that appears when
the alarm is triggered. If there
is no number in this field, this
indicates a fixed shot.
This is the dome and input
that will trigger an alarm
when a change in state is
detected.
This is the dome whose
video appears on the
monitor when the alarm
occurs.
This is the specific
output that initiates
when the alarm is
triggered.